solar.halowerk.com

6 x402 APIs served from solar.halowerk.com

Every listing from solar.halowerk.com that ToolVet tracks. Each one is called on a schedule without paying and scored out of 100.

At a glance

Listings
6 x402 APIs
Passing at the latest check
6 of 6
Uptime, 30 days
100% on average across 6 listings
Price
$0.002 to $0.005 per call
Trust score
78 to 82, median 80
Paying wallets, 30 days
4 on its busiest listing
Verified owner
None
Security findings
None found
Listed since
11 Oct 2026

The x402 Bazaar counts paying wallets per listing. A wallet that paid two listings counts twice. So the Bazaar saw between 4 and 13 different wallets paying solar.halowerk.com in 30 days.

All 6 listings

Ranked by trust score.

  • 82trust
    Low Wattage Cookingsolar.halowerk.com

    Uses rated electrical power, food mass, start and target temperature, specific heat and an explicit efficiency range supplied by the caller. Optional vessel heat, evaporation and a caller-defined hold phase can be included. It contains no recipes, recipe text, food-specific cooking claims or hidden food database; the output separates the thermodynamic lower bound from the practical range and is not a food-safety clearance.

    x402 APIDeveloper tools
    $0.003per call on Base
    100% uptime, 127 ms, 4 paying agentsPassing, checked 3 h ago
  • 80trust
    Building Heat Demandsolar.halowerk.com

    Computes a transparent planning estimate for space-heating demand. The method is not DIN, VDI, GEG or PHPP and must not be used as regulatory proof. It combines transmission heat loss from each envelope component, ventilation heat loss from heated volume and air changes, monthly heating degree days from the nearest DWD 1991-2020 temperature-normal station, stated internal gains and optional domestic hot water.

    x402 APIOther
    $0.004per call on Base
    100% uptime, 124 ms, 2 paying agentsPassing, checked 3 h ago
  • 80trust
    Inverter Load Checksolar.halowerk.com

    Continuous load is the sum of the running watts of all appliances marked as simultaneous. The surge check adds the largest single starting surge on top of the continuous load, which is the case that trips an inverter; simultaneous starts of two motors are reported separately as a second figure. Starting factors and power factors are design rules of thumb per appliance class and are stated in the response, they are not device data.

    x402 APIOther
    $0.002per call on Base
    100% uptime, 136 ms, 2 paying agentsPassing, checked 2 h ago
  • 80trust
    Autonomy Forecastsolar.halowerk.com

    Daily energy balance and straight run-down from the figures supplied. Solar input is caller data in watt-hours per day; nothing is fetched and no weather is assumed. Time to empty means time to the reserve floor, not to zero. Idle draw and conversion efficiency apply to AC loads only. Ageing, temperature and Peukert behaviour are not modelled, which matters for lead acid far more than for LiFePO4.

    x402 APIWeather & location
    $0.003per call on Base
    100% uptime, 105 ms, 2 paying agentsPassing, checked 2 h ago
  • 80trust
    Battery Cyclesolar.halowerk.com

    Integrates the supplied current over time by the trapezoidal rule, so the result is only as good as the sampling interval; gaps longer than the stated max_gap_seconds are excluded and reported. Sign convention: positive current is charging, negative is discharging. Internal resistance is estimated from the largest current step in the series and is a rough figure, not a measurement under defined conditions.

    x402 APIOther
    $0.004per call on Base
    100% uptime, 105 ms, 2 paying agentsPassing, checked 3 h ago
  • 78trust
    Off Grid Weather Alarmsolar.halowerk.com

    Uses the nearest current DWD MOSMIX_L station forecast, or a station explicitly supplied by the caller. Global irradiance drives a transparent PV estimate and forecast wind speed drives a stated generic turbine curve; neither replaces a site-specific yield model. A constant hourly load and optional battery are simulated over 12 to 120 hours. The result is an installation-risk signal, not an official weather warning, emergency alert or guarantee of supply.

    x402 APIWeather & location
    $0.005per call on Base
    100% uptime, 123 ms, 1 paying agentsPassing, checked 17 min ago

Watch these listings in one feed

How these numbers are made

Each listing is called on a schedule without paying. Listings with usage or a verified owner are checked about every 30 minutes, others about every 6 hours. Uptime is the share of passing checks over 30 days, averaged across this provider's listings. Trust scores follow the published method. The figures on this page can be a few minutes behind the latest checks, and listings hidden after review aren't counted.