solar.halowerk.com
6 x402 APIs served from solar.halowerk.com
Every listing from solar.halowerk.com that ToolVet tracks. Each one is called on a schedule without paying and scored out of 100.
At a glance
- Listings
- 6 x402 APIs
- Passing at the latest check
- 6 of 6
- Uptime, 30 days
- 100% on average across 6 listings
- Price
- $0.002 to $0.005 per call
- Trust score
- 78 to 82, median 80
- Paying wallets, 30 days
- 4 on its busiest listing
- Verified owner
- None
- Security findings
- None found
- Listed since
- 11 Oct 2026
The x402 Bazaar counts paying wallets per listing. A wallet that paid two listings counts twice. So the Bazaar saw between 4 and 13 different wallets paying solar.halowerk.com in 30 days.
All 6 listings
Ranked by trust score.
- 82trustLow Wattage Cookingsolar.halowerk.com
Uses rated electrical power, food mass, start and target temperature, specific heat and an explicit efficiency range supplied by the caller. Optional vessel heat, evaporation and a caller-defined hold phase can be included. It contains no recipes, recipe text, food-specific cooking claims or hidden food database; the output separates the thermodynamic lower bound from the practical range and is not a food-safety clearance.
$0.003per call on Base100% uptime, 127 ms, 4 paying agentsPassing, checked 3 h ago - 80trustBuilding Heat Demandsolar.halowerk.com
Computes a transparent planning estimate for space-heating demand. The method is not DIN, VDI, GEG or PHPP and must not be used as regulatory proof. It combines transmission heat loss from each envelope component, ventilation heat loss from heated volume and air changes, monthly heating degree days from the nearest DWD 1991-2020 temperature-normal station, stated internal gains and optional domestic hot water.
$0.004per call on Base100% uptime, 124 ms, 2 paying agentsPassing, checked 3 h ago - 80trustInverter Load Checksolar.halowerk.com
Continuous load is the sum of the running watts of all appliances marked as simultaneous. The surge check adds the largest single starting surge on top of the continuous load, which is the case that trips an inverter; simultaneous starts of two motors are reported separately as a second figure. Starting factors and power factors are design rules of thumb per appliance class and are stated in the response, they are not device data.
$0.002per call on Base100% uptime, 136 ms, 2 paying agentsPassing, checked 2 h ago - 80trustAutonomy Forecastsolar.halowerk.com
Daily energy balance and straight run-down from the figures supplied. Solar input is caller data in watt-hours per day; nothing is fetched and no weather is assumed. Time to empty means time to the reserve floor, not to zero. Idle draw and conversion efficiency apply to AC loads only. Ageing, temperature and Peukert behaviour are not modelled, which matters for lead acid far more than for LiFePO4.
$0.003per call on Base100% uptime, 105 ms, 2 paying agentsPassing, checked 2 h ago - 80trustBattery Cyclesolar.halowerk.com
Integrates the supplied current over time by the trapezoidal rule, so the result is only as good as the sampling interval; gaps longer than the stated max_gap_seconds are excluded and reported. Sign convention: positive current is charging, negative is discharging. Internal resistance is estimated from the largest current step in the series and is a rough figure, not a measurement under defined conditions.
$0.004per call on Base100% uptime, 105 ms, 2 paying agentsPassing, checked 3 h ago - 78trustOff Grid Weather Alarmsolar.halowerk.com
Uses the nearest current DWD MOSMIX_L station forecast, or a station explicitly supplied by the caller. Global irradiance drives a transparent PV estimate and forecast wind speed drives a stated generic turbine curve; neither replaces a site-specific yield model. A constant hourly load and optional battery are simulated over 12 to 120 hours. The result is an installation-risk signal, not an official weather warning, emergency alert or guarantee of supply.
$0.005per call on Base100% uptime, 123 ms, 1 paying agentsPassing, checked 17 min ago
How these numbers are made
Each listing is called on a schedule without paying. Listings with usage or a verified owner are checked about every 30 minutes, others about every 6 hours. Uptime is the share of passing checks over 30 days, averaged across this provider's listings. Trust scores follow the published method. The figures on this page can be a few minutes behind the latest checks, and listings hidden after review aren't counted.