83trust / 100

Ampworth

by ampworth.com in Other

MCP serverPassing, checked 6 h ago

UK solar PV and heat pump calculators, with guides, on one server. Follows the MCS methods. No key.

https://ampworth.com/mcp
Tools
15
open to any client
Uptime
100%
last 30 days
Response time
176 ms
416 ms slowest 5%
Last check
Passed
6 h ago, next any minute now

Scan it nowHow to connect

Reliability

All checks passedSome failedAll failedNot checked

Status and outage history · Atom feed · Watch with other listings

How to connect

Add it to any MCP client that supports remote servers.

{
  "mcpServers": {
    "ampworth": {
      "type": "http",
      "url": "https://ampworth.com/mcp"
    }
  }
}

15 tools

  • connection_route

    Work out which ENA connection procedure a domestic installation of solar panels, batteries or both falls under: connect first and notify the distribution network operator within 28 days, or apply and wait for approval before anything is connected. The rules are the ENA's…

  • get_document

    Fetch the full text of one guide, article or set of questions by its slug, as Markdown, not HTML. Slugs come from search_documents or list_documents. The answer carries the MCS documents the text draws on, and the ids of any calculators on this site that do the arithmetic the…

  • heat_pump_noise

    Calculate the sound pressure level an air source heat pump produces at an assessment position, and whether it meets the 37 dB(A) permitted development noise limit, using the method in MCS 020. The formula is Lp = Lw + 10 log(Q / 4.pi.r^2) - Ab. Lw is the A-weighted sound POWER…

  • heat_pump_running_cost

    Compare what a household spends heating on its current fuel with what the same heat would cost from a heat pump. The heat demand is worked out from the household's own metered fuel use, not from a model, because a year of bills describes a particular house far better than any…

  • heat_pump_size

    Estimate the heat pump a UK house needs, and what it would cost to run against the fuel it burns now. IMPORTANT: MIS 3005-D requires a heat pump to be sized from a room-by-room heat loss calculation to BS EN 12831, and nothing here replaces that. Say so whenever you report a…

  • hot_water_cylinder

    Work out the daily hot water demand of a dwelling and the size of cylinder a heat pump needs, using the formula in MIS 3005-D 3.5.2 and the BS 6700 guidance reproduced in MGD 007. The demand is 45 litres a day for each of N, where N is the greater of the number of bedrooms plus…

  • list_calculators

    Lists every calculator on this server, with the standard behind it and whether it is the whole-system sizing calculator or one of the single-method ones, plus the reference data a caller needs to build a valid request: the compass directions and their orientations, the shading…

  • list_documents

    Lists every document, optionally filtered by kind ('guide', 'article' or 'faq'), by category, or, for guides, by the reader they are written for. Guides are shelved by perspective: 'considering', 'buying', 'selling', 'installing' and 'learning'. The first four are plain language…

  • radiator_flow_temperature

    Work out the flow temperature a heat pump must produce to heat a room through a given radiator, and the resulting MCS Heat Emitter Guide star rating, following section 4 of MGD 007. This is the calculation that decides whether a heat pump will be cheap or expensive to run. A…

  • room_heat_loss

    Calculate the design heat loss of a single room in watts, following BS EN 12831 as MIS 3005-D applies it. This is the figure a heat pump is sized from and the figure the radiator in that room must be able to deliver. BS EN 12831 is a room-by-room method. Run this once for each…

  • search_documents

    Search the guides, articles and questions for material on a UK home energy subject. Use this first, before answering from memory, whenever a question concerns UK heat pump or solar PV practice: how a system is sized, what a standard requires, what a quotation should contain…

  • solar_pv_output

    Estimate the annual AC electricity output of a UK solar photovoltaic system, in kWh, using the standard estimation method that MIS 3002 requires every MCS certified installer to use. The method is: annual output = kWp x Kk x SF, where Kk is read from the MCS irradiance dataset…

  • solar_pv_self_consumption

    Estimate what proportion of a domestic solar PV system's annual output is consumed in the house and what proportion is exported, using the lookup tables in MGD 003. The tables are not a model. They come from half-hourly monitoring of real British households by Loughborough…

  • solar_pv_shading

    Convert a completed MCS sunpath shading assessment into a shade factor, using the procedure in MGD 005. The MCS sunpath chart is divided into 84 segments, each worth one per cent of the year's useful irradiance. An assessor stands at the middle of where the array will go, plots…

  • solar_pv_system_size

    Work out the solar PV system a UK home needs: the capacity in kWp, the number of panels, the battery to go with it, and what it would do to the electricity bill. This runs the MCS arithmetic backwards. The other solar calculators here each answer one question about a system…

Security scan

No findings

We scan names, descriptions and tool definitions for hidden instructions and other prompt-injection patterns.

Recent checks

WhenResultHTTPTime
6 h agoPassed200176 ms
17 h agoPassed200185 ms
28 h agoPassed20089 ms
39 h agoPassed200416 ms