SparkQuote NEC calculators
by sparkquote.ai in Other
NEC 2023 electrical calculators: wire size, ampacity, voltage drop, conduit fill, box fill, load.
https://sparkquote.ai/mcp- Tools
- 10
- open to any client
- Uptime
- 100%
- last 30 days
- Response time
- 295 ms
- 1.2 s slowest 5%
- Last check
- Passed
- 6 h ago, next in 18 min
Reliability
Status and outage history · Atom feed · Watch with other listings
How to connect
Add it to any MCP client that supports remote servers.
{
"mcpServers": {
"sparkquote-nec-calculators": {
"type": "http",
"url": "https://sparkquote.ai/mcp"
}
}
}10 tools
- wire_size
Minimum conductor size for a circuit: NEC Table 310.16 ampacity at the termination temperature rating, the 240.4(D) small-conductor limits, voltage drop over the run, and the Table 250.122 equipment grounding conductor, increased in proportion under 250.122(B) when voltage drop…
- voltage_drop
Voltage drop for a given conductor size, current and one-way length, single- or three-phase, from NEC Chapter 9 Table 8 circular mils (VD = 2·K·I·L / CM, or √3 for three-phase).
- watts_to_amps
Current drawn by a load in watts at a voltage and power factor, single- or three-phase, plus the 125% continuous-load value.
- conduit_fill
Percent fill and maximum number of THHN/THWN-2 conductors of one size in EMT or PVC Schedule 40, from NEC Chapter 9 Tables 1, 4 and 5.
- box_fill
Minimum outlet box volume from NEC 314.16(B): conductor, device (2 each), clamp and grounding allowances times the Table 314.16(B) volume for the largest conductor.
- load_calculator
Dwelling service load by the NEC 220.82 optional method: 3 VA/ft² lighting, small-appliance and laundry circuits, fixed appliances, demand factor, heating or cooling, and the minimum standard service size. Leave an appliance out to count it as 0 VA.
- ohms_law
Ohm's law and power: give exactly two of voltage, current, resistance and power; the other two are calculated.
- panel_schedule
Lays circuits out on a 120/240 V single-phase or 208Y/120 V three-phase panel and totals the load per phase with the imbalance.
- bid_calculator
Electrical bid price from materials, markup, labor hours and rate, job costs, overhead and a target net margin (price = break-even / (1 − margin)).
- nec_ampacity
Allowable ampacity of one insulated conductor from NEC Table 310.16 (not more than three current-carrying conductors in a raceway or cable, 30°C ambient), before any adjustment or correction factors and before the 240.4(D) small-conductor limits.
Security scan
No findings
We scan names, descriptions and tool definitions for hidden instructions and other prompt-injection patterns.
Recent checks
| When | Result | HTTP | Time |
|---|---|---|---|
| 6 h ago | Passed | 200 | 412 ms |
| 19 h ago | Passed | 200 | 250 ms |
| 31 h ago | Passed | 200 | 527 ms |
| 43 h ago | Passed | 200 | 282 ms |
| 2 days ago | Passed | 200 | 327 ms |
Show 10 older checks
| 3 days ago | Passed | 200 | 247 ms |
| 3 days ago | Passed | 200 | 268 ms |
| 4 days ago | Passed | 200 | 734 ms |
| 4 days ago | Passed | 200 | 271 ms |
| 5 days ago | Passed | 200 | 470 ms |
| 5 days ago | Passed | 200 | 268 ms |
| 5 days ago | Passed | 200 | 198 ms |
| 6 days ago | Passed | 200 | 310 ms |
| 6 days ago | Passed | 200 | 281 ms |
| 7 days ago | Passed | 200 | 279 ms |